Check to see if your voltage is dropping, your wire size might be too long or too small,
or your service could be weak.
Step 1 - Go to your si...
Sun, 5 Oct, 2014 at 11:38 AM
By switching any of the two three phase lines, you can reverse the rotation of your equipment or machine.
Note: All controls should be run from L1 and L2...
Tue, 18 Mar, 2014 at 7:17 PM
Blowing a start capacitor could be caused by a few different reasons.
1. Too Frequent starts. Phase converter should not be cycled on and off frequ...
Wed, 10 Sep, 2014 at 3:24 PM
Few reason this could happen. Voltage Dropping or Phase Converter is overloaded.
1. You could be having a voltage drop due to, weak service, too smal...
Wed, 24 Sep, 2014 at 3:32 PM
Step 1 - Check to make sure your converter is big enough. If not, a second converter of equal size can be installed in parallel to your converter to double...
Mon, 25 Aug, 2014 at 12:09 PM
Step 1 - Check connection. L1 and L2 should read 220 volts from line to line, and these lines are 120 volts from line to ground.
Step 2 - Check to mak...
Sun, 12 Oct, 2014 at 11:58 AM
Step 1 - Check to make sure the idler motor is hooked up for low voltage RUN (208-240 volts) Make sure every lead in the box is being used or connected.
...
Sun, 5 Oct, 2014 at 10:13 AM
Step 1 - It may be normal to run warm and hot under a heavy load, check your voltage balance, if the volts are balance, then your idler is connected right ...
Mon, 28 Jul, 2014 at 8:18 AM
Step 1 - All controls should be run from L1 and L2 ( the single phase lines )
Thu, 3 Oct, 2013 at 12:22 PM
Step 1 - All controls should be run from L1 and L2 ( the single phase lines )
Step 2 - You are probably getting a low voltage error, slow the accel...
Mon, 10 Mar, 2014 at 1:55 PM